Bosch Solution 3000 Manual Download

Bosch Solution 3000 Manual Download

Congratulations on selecting the Solution 2000 / Solution 3000 Control Panel to protect you and your property. To obtain the most from your unit, take time to read through this manual and familiarize yourself with the numerous outstanding operating features of this system.

In all aspects of planning, engineering, styling, operation, convenience, and adaptability, we have sought to anticipate your every possible requirement.

Programming simplicity and speed were some of the major considerations and we believe that
our objectives in this area were more than satisfied.
This manual explains all aspects of operating the Bosch Solution 3000 control panel. All system parameters and
options are detailed; however, suitability is left up to the individual. Every system can be
tailored to meet all requirements quickly and easily.

To Arm in AWAY mode:
Enter your user code followed by the [AWAY] button (for example,
[2580#])
OR…
Press the [0] button, followed by [AWAY] button
Two beeps sound and the AWAY indicator displays. Exit Time
starts counting.

To Disarm – Enter your user code followed by the [STAY] button. Two beeps
sound and the AWAY indicator extinguishes.

To arm in STAY mode – Press the [0] button followed by [STAY]

Only the Master Code holder can add other system user codes
1. Enter your Master Code, followed by [1] and the [AWAY] button (for example, [25801#]).
Three beeps are heard and the STAY and AWAY indicators flash.

 

2. Enter the User Code number (1 to 32), followed by the [AWAY] button (for example, [2#] =
User 2, [8#] = User 8).
Two beeps are heard and the selected user number displays on
the codepad indicators.

3. Enter the digits required for the new code followed by the [AWAY] button (for example, for
User Code 5768, enter [5768], then [AWAY])
Two beeps are heard and the STAY and AWAY indicators
turn off.

To add or change other User Codes, repeat this procedure as many times as required.

Only the Master Code holder can delete other system user codes.
How to Delete a User Code
1. Enter your Master Code, followed by [1] and the [AWAY] button (for example, [25801], [AWAY]).
Three beeps sound and the STAY and AWAY indicators flash.

 

2. Enter the user code number (1 to 32), followed by the [AWAY] button (for example, [2] [AWAY]=
User 2, [16] [AWAY]= User 16).
Two beeps sound and the selected user number displays on the
codepad indicators.

3. Press the [STAY] button to delete the selected User Code.
Two beeps are heard and the STAY
and AWAY indicators turn off.

To delete other User Codes, repeat this procedure as many times as required.

Bosch Solution 3000 Fault Chart

Zone Indicator Fault Description Hold Down Button… Zone Indicator Fault Condition
1 System Fault 1 1 Battery Fail
      2 Time & Date
      3 RF Receiver Fail
      4 External Siren Fail
      5 Phone Line Fail
      6 EEPROM Failure
      7 Fuse Fail
      8 Mains Power Fail
2 RF Low Battery 2 1 to 8 Zone 1 to 8 has a Detector Low Batt
3 Zone Tamper Alarm 3 1 to 8 Zone 1 to 8 Tamper Alarm
4 Sensor Watch Fault 4 1 to 8 Zones 1 to 8 Sensor Watch Fail
5 RF Sensor Watch Fail 5 1 to 8 Zones 1 to 8 RF Sensor Watch Fail
6 Communication Fail 6 1 Receiver 1 Fail
      2 Receiver 2 Fail

Need more help?

Melbourne Alarms provide high quality, fast and affordable servicing and repairs to all Bosch security systems. We have installed more than 12,000 security systems in Melbourne over the past 26 years with thousands of happy customers. If you’re experiencing problems with your system, then give us a call or send an email. We’d be more than happy to assist or perhaps even discuss upgrading your existing system. Give us a call to arrange an appointment with one of our technicians.